Supplementary Material, Appendix G – G.36

APPENDIX G – Pumps and Turbines

MainPreviousNext

Surge Analysis and the Wave Plan Method

Supplementary Material: Example Problems and Solutions

Appendix G – Problem 36

G.36 A Kaplan turbine was used to generate electricity from a water source with a flow capacity of 10 m3/s and an available head of 20m at the inlet to the turbine. What is the power generation capacity of this turbine if the highest water-to-wire efficiency is 85%?


Summary of revisions to this page:

Date/Revision